Solving the problem of Oil leakage of Industrial Dust-removing centrifugal Fan

Wuxi JN Fan Co.,Ltd | Updated: May 31, 2018
Source:

The industrial dust-removing centrifugal fan is a volumetric fan, and the air volume is proportional to the number of revolutions. Dust-removing centrifugal fans used in: factories, environmental protection industry, metallurgy, chemical, mining, textile, food and other industries.

企业微信截图_20180531165550.jpg

If you don't pay attention to the phenomenon of oil leakage in the process of industrial dust removal centrifugal fan, how to solve the problem of industrial dust removal centrifugal fan oil leakage?

1. When the oil leak into the housing due to the blockage of the ventilator, it is necessary to clear the vent of the dust removing fan and install a cock with aperture in the middle cavity.

2. The pressure value of the industrial dust-removing centrifugal fan is higher than the specified value, and the pressure of the equipment is adjusted to the normal level.

3 . The fuel tank level is high , the oil drain port leaks oil , and the oil level needs to be reduced .

4. dust-removing centrifugal fan seal wear, cause shaft end oil leakage, need to replace the equipment seal.

The above is how to solve the problem of industrial dust centrifugal fan oil leakage. The oil loss can be reduced and the working efficiency can be improved when the oil leakage occurs in the dust removal centrifugal fan.

When using industrial dust centrifugal fan, it is necessary to do regular maintenance work, clean dust from centrifugal fan and add lubricating oil regularly to reduce friction.http://www.jnblower.com/