Emergency stop of Fan in installation and Test run
Sep 24, 2019
The fan shall be shut down when one of the following conditions is found during the installation of the test run:
1 friction between the rotor and the casing
2 Sudden increase in body vibration and strong
3 The bearing temperature exceeds the prescribed and continues to rise
4 The harmful gas delivered is much
5 The current suddenly rises and does not return to its original position within 1-2 min
6 Oil supply interruption due to blockage of oil pump pipeline or other reasons
7 Sudden interruption of cooling water
8 In other cases, what happens is of serious harm.https://www.jnblower.com/